ACCELERATE YOUR EXAM PREPARATION WITH EXIN CDCP EXAM QUESTIONS

Accelerate Your Exam Preparation With EXIN CDCP Exam Questions

Accelerate Your Exam Preparation With EXIN CDCP Exam Questions

Blog Article

Tags: Valid CDCP Guide Files, Certification CDCP Training, CDCP Valid Exam Braindumps, Dumps CDCP PDF, CDCP Frequent Updates

Our Certified Data Centre Professional (CDCP) exam questions are totally revised and updated according to the changes in the syllabus and the latest developments in theory and practice. And the study materials are based on the past years of the exam really and industry trends through rigorous analysis and summary. We carefully prepare the CDCP test guide for the purpose of providing high-quality products. All the revision and updating of products can graduate the accurate information about the CDCP Guide Torrent you will get, let the large majority of student be easy to master and simplify the content of important information. Our product CDCP test guide delivers more important information with fewer questions and answers, in order to easy and efficient learning.

EXIN CDCP Exam Syllabus Topics:

TopicDetails
Topic 1
  • Auxiliary Systems: The topic covers water leak detection systems, data centre monitoring requirements, EMS, BMS and DCIM.
Topic 2
  • Designing a Scalable Network Infrastructure: It covers ANSI
  • TIA-942 cabling hierarchy, network redundancy, structured Cabling System, and planning considerations.
Topic 3
  • Physical Security and Safety: Sub-topics are about physical security considerations and physical safety considerations.
Topic 4
  • Fire Safety
  • Protection: This topic gives an understanding of standards for fire suppression, detection systems, total flooding fire suppression techniques, and handheld extinguishers. Additionally, it covers Signage and safety.
Topic 5
  • Water Supply: This topic is all about water supply techniques and application areas.
Topic 6
  • Data Centre Location, Building and Construction: It focuses on appropriate sites and components of an effective data centre and supporting facilities setup.
Topic 7
  • Electro Magnetic Fields: The topic deals with effects of EMF on human health and equipment (H)EMP, standards, and EMF shielding solutions.
Topic 8
  • Raised Floor
  • Suspended Ceiling: The topic discusses applicable standards, signal reference grid, and disability act and regulations.
Topic 9
  • Light: This topic covers light fixture types and placement, emergency lighting, and emergency Power Supply (EPS).
Topic 10
  • Cooling Infrastructure: The topic focuses on liquid immersion cooling, supplemental cooling options, sensible and latent heat definitions, and temperature and humidity recommendations.
Topic 11
  • Equipment Racks: It discusses power rail
  • strip options, security considerations, and rack standards, properties and selection criteria.

>> Valid CDCP Guide Files <<

Certification CDCP Training - CDCP Valid Exam Braindumps

Are you tired of feeling overwhelmed and unsure about how to prepare for the Certified Data Centre Professional (CDCP) (CDCP) exam? Are you ready to take control of your future and get the CDCP certification you need to accelerate your career? If so, it's time to visit ValidExam and download real EXIN CDCP Exam Dumps. Our team of experts has designed a CDCP Exam study material that has already helped thousands of students just like you achieve their goals. We offer a comprehensive CDCP practice exam material that is according to the content of the EXIN CDCP test.

EXIN Certified Data Centre Professional (CDCP) Sample Questions (Q13-Q18):

NEW QUESTION # 13
What is the minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems?

  • A. 120 cm / 47 inches
  • B. 64 cm / 25 inches
  • C. 46 cm / 18 inches
  • D. 60 cm / 24 inches

Answer: C

Explanation:
The minimum clearance space required below water sprinkler heads and nozzles of gas-based fire suppression systems is 46 cm / 18 inches, according to the CDCP Preparation Guide1 and OSHA regulation 29 CFR
1910.159 © (10)2. This clearance space is necessary to ensure that the sprinkler spray or gas discharge can reach the fire and cover the protected area effectively. Any material or obstruction below this clearance space can interfere with the sprinkler or gas distribution and reduce the fire suppression performance. Therefore, building owners and managers should ensure that all storage and objects in the data centre are kept below this clearance space, and that the clearance space is maintained at all times.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Clarification of OSHA regulation 29 CFR
1910.159©(10), Sprinkler ...3, page 1, section 1


NEW QUESTION # 14
From the list below, which sensor detects smoke the fastest?

  • A. Photoelectric detector
  • B. VESDA/HSSD
  • C. Sprinkler bulbs
  • D. lonization detector

Answer: B

Explanation:
VESDA (Very Early Smoke Detection Apparatus) or HSSD (High Sensitivity Smoke Detection) systems are the fastest smoke sensors among the options listed. These systems use a network of pipes to draw air samples from the protected area and analyze them using a laser-based detection chamber. VESDA/HSSD systems can detect smoke at very low concentrations, typically in the range of 0.005 to 20 percent obscuration per meter.
This means they can provide early warning of a fire before it becomes visible or spreads. VESDA/HSSD systems are ideal for data centers and other critical facilities that require high levels of fire protection and minimal downtime.
References: VESDA Smoke Detection Systems - Xtralis, HSSD Smoke Detection Systems - Fire Protection Online, Smoke Detection in Data Centers - Siemens.


NEW QUESTION # 15
Mean time between failures is best considered a measure of:

  • A. Cost
  • B. Duration
  • C. Reliability
  • D. Size

Answer: C

Explanation:
Mean time between failures (MTBF) is a measure of the reliability of a system or component. It represents the average time that a system or component will operate before it fails. The higher the MTBF, the more reliable the system or component is. MTBF is calculated by dividing the total time of operation by the number of failures that occur during that time. MTBF is used to compare the reliability of similar systems or components, and to help with maintenance planning, inventory management, and system design.
References: EPI Data Centre Training Framework, CDCP Preparation Guide, Reliability Metrics 101: Mean Time Between Failure (MTBF)


NEW QUESTION # 16
What is the most preferred unit of measure for cooling capacity?

  • A. BTU
  • B. Ton
  • C. Horsepower
  • D. Watt

Answer: D

Explanation:
Cooling capacity is the measure of a cooling system's ability to remove heat from a space. The most preferred unit of measure for cooling capacity is watt (W), which is the SI unit for power. Watt is defined as the amount of energy transferred or converted per unit time. One watt is equal to one joule of energy per second. Using watt as the unit of measure for cooling capacity allows for easy comparison and calculation of the cooling performance and efficiency of different cooling systems.
Other units of measure for cooling capacity are ton, BTU, and horsepower, but they are less common and less convenient than watt. Ton is a unit of measure that describes how much water at freezing temperature can be frozen in 24 hours, equivalent to 3.5 kW or 12,000 BTU/h. BTU (British Thermal Unit) is a unit of measure that describes the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit, equivalent to 0.293 W. Horsepower is a unit of measure that describes the rate at which work is done, equivalent to 746 W.
References:
*Data Centre Professional (CDCP®) Reference Materials, page 8, section 2.1.1
*Data Centre Professional (CDCP®) Preparation Guide, page 11, section 2.1.1
*Cooling capacity - Wikipedia
*Air Conditioner BTU Calculator
*Air conditioning 101: Basics, working principle and sizing ... - GlobalSpec
*How is cooling capacity measured? - Sage-Advices
*Everything You Need to Know About Cooling Capacity


NEW QUESTION # 17
Which Class of Fires involves cooking appliances?

  • A. Class C
  • B. Class B
  • C. Class K
  • D. Class A

Answer: C

Explanation:
According to the EPI Data Centre Professional (CDCP®) Preparation Guide, Class K fires involve cooking appliances that use combustible cooking media such as vegetable or animal oils and fats (page 28). Class K fires require special extinguishing agents that can suppress the high-temperature flames and prevent re-ignition. Class K fires are different from Class B fires, which involve flammable liquids such as gasoline, oil, or paint.
References:
*EPI Data Centre Professional (CDCP®) Preparation Guide, page 28
*Fire Classes and Extinguishing Agents | The Fire Equipment Manufacturers' Association


NEW QUESTION # 18
......

The ValidExam is committed to making the Channel Partner Program CDCP exam preparation journey simple, smart, and swift. To meet this objective the ValidExam is offering EXIN CDCP practice exam questions with top-rated features. These features are updated and real Certified Data Centre Professional (CDCP) CDCP exam questions, availability of Channel Partner Program Certified Data Centre Professional (CDCP) CDCP Exam real questions in three easy-to-use and compatible formats, three months free updated Certified Data Centre Professional (CDCP) CDCP exam questions download facility, affordable price and 100 percent Certified Data Centre Professional (CDCP) CDCP exam passing money back guarantee.

Certification CDCP Training: https://www.validexam.com/CDCP-latest-dumps.html

Report this page